17
3.
Press the Minutes + and
panel announces the correct minutes.
4.
Press Done. The panel announces the set time.

Adding (Learning) Sensors

These instructions describe how to add sensors, touchpads and other system devices
into panel memory. The panel recognizes a sensor when you press a sensor program
button, press and release a tamper switch, press a sensor test button, or put a sensor into
alarm.
Note
The hardwire inputs must have sirens or hardwire sensors with 47k Ohm resistors connected
between the DCOUT and HWIN1 or HWIN2 terminals before learning in a sensor. If one of
these connections is not made, the panel will learn in a hardwire zone.
Note
If you are installing a sensor on a gun case, jewelry box, or similar usage, and the sensor is
active in level one, you must sub-disarm to avoid putting the panel into alarm when the sensor
and the magnet are separated.
The following table, "Device Programming," describes the programming button loca-
tion for each device.
Device
Door/Window Sensor
Motion Sensor
Smoke Sensor
Keychain Touchpad
ELM Keychain Touchpad
Remote Handheld Touchpad
2-Way RF Touchpad
Hardwire Sensors
CO Alarm
Freeze & Water
Dialog RF Electronic Thermostat
keys and listen to the voice prompts. Stop when the
Device Programming
To Program
Press button on top of sensor (cover removed)
or trip tamper
Press button on back of sensor (mounting plate
removed) or trip tamper
Trip tamper, press test button, remove from
base or put sensor in alarm
Press and hold Lock & Unlock buttons together
Press Press
Press
Hold until LED is done flashing.
Press the EMERGENCY buttons
Press Lights Off button 6 times
Separate sensor from magnet
Plug in the module wait 5-7 seconds press and
hold the test button for 9 beeps
Trip tamper or press and hold button on top of
the sensor (cover removed) until control panel
confirms programming. If button is not held
down long enough, SYSTEM STATUS reports
sensor as open.
Panel automatically recognizes thermostat dur-
ing thermostat power-up.
Hold
Flash Flash Flash
Flash Flash
Hold
Hold
Flash
Simon Security System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Interlogix 60-875 simon

Table of Contents