Option 07: Account Number; Option 08: Phone Lock; Option 09: Downloader Code; Option 10: Entry Delay - GE Simon Installation Instructions Manual

Hide thumbs Also See for Simon:
Table of Contents

Advertisement

Note
Pressing DONE is required if
you enter fewer than 26 dig-
its. The phone number is
automatically stored without
pressing DONE if all 26
places are used.
Note
The CID format only sup-
ports account numbers with
letters B through F, or num-
bers 0 through 9 (or a com-
bination of those letters and
numbers).
Note
Pressing DONE is required if
you enter fewer than 10
characters. The account
number is automatically
stored without pressing
DONE if 11 characters are
entered, of which only the
first 10 are stored.
Note
The downloader code
should always be changed
from the default setting to
avoid competitor theft.
Note
For UL listed systems, the
entry delay must not exceed
45 seconds.
Simon Security System
¾ To set Downloader Phone Number, press:
Add—Option #—06—Up to 26 digits—DONE.
¾ To delete Downloader Phone Number, press:
Delete—Option #—06—DONE.
Option 07: Account Number (Default = 00000)
Lets you program up to a 10-character alphanumeric account number (on) or delete an
existing account number (off).
To enter letters (A - F only), press 9 then the Minutes + button. The panel announces
the letter A. Continue pressing the Minutes + button to progress through the alphabet.
¾ To set Account Number, press:
Add—Option #—07—Up to 10 characters—DONE.
¾ To delete Account Number, press:
Delete—Option #—07—DONE.
Option 08: Phone Lock (Default = off)
Prevents resetting of phone/reporting related Options 04, 05, 06, 08, 09, 12, 13, 54 and
Utility Code when a memory clear is performed (on), or resets these options to their
default values when a memory clear is performed (off).
¾ To turn on Phone Lock, press:
Add—Option #—08—DONE.
¾ To turn off Phone Lock, press:
Delete—Option #—08—DONE.
Option 09: Downloader Code (Default = 12345)
Lets you set a unique 5-digit code that is required for initiating ToolBox sessions (on)
or sets the code to its default (off).
The code must be 5 digits long and can range from 00000 to 99999. The Downloader
Code must match the downloader access code in the ToolBox account to perform
ToolBox sessions.
¾ To set Downloader Code, press:
Add—Option #—09—5-digit code—DONE.
¾ To delete Downloader Code (return to default), press:
Delete—Option #—09—DONE.
Option 10: Entry Delay (Default = 030 sec)
Determines how much time the user has to disarm the system after entering the armed
premises through a designated delay door, before an alarm occurs. Beeps sound during
the entire delay time to remind the user to disarm the system.
When turned on, the Entry Delay can be set from 005-254 seconds (030-254 if SIA
Limits Option 69 is on). All entries must be 3 digits. When turned off, the Entry Delay
is set to 005 seconds.
¾ To set Entry Delay, press:
Add—Option #—10—3-digit delay time—DONE.
¾ To reset Entry Delay (return to default), press:
Delete—Option #—10—DONE.