IBM eServer pSeries 610 6C1 Installation Manual page 113

Ibm eserver pseries 610 unix server installation guide
Hide thumbs Also See for eServer pSeries 610 6C1:
Table of Contents

Advertisement

Symptom
The System Management Services menu is
displayed.
The system appears to be stopped, the disk
activity light is on continuously, and a beep was
heard from the system unit.
The system stops with the message STARTING
SOFTWARE PLEASE WAIT displayed.
The message The system will continue the
boot process is displayed continuously on the
system unit's console.
Action
The device or media that you are attempting to
boot from might be faulty.
1. Check the SMS error log for any errors. To
check the error log:
v Select utilities
v Select error log
v If an error is logged, check the time
stamp.
v If the error was logged during the current
boot attempt, record it and report it to
your service representative.
v If no recent error is logged in the error
log, continue to the next step below.
2. If you are attempting to load the Online
Diagnostics, try loading the Standalone
Diagnostics. Otherwise, record error code
M0SCSI01 and report the problem to the
service organization.
Record error code M0MEM001 and report the
problem to the service organization.
Report error code M0BT0000.
Report error code M0SCSI01.
Chapter 5. Hardware Problem Determination
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver pseries 610 6e1

Table of Contents