Step 4
This step attempts to load the Standalone diagnostics.
1. Turn off the power.
2. Turn on the power.
3. Insert the diagnostic CD-ROM into the CD-ROM drive.
4. If the keyboard indicator displays, press F5 on the directly attached keyboard, or 5
on the ASCII keyboard, to indicate that standalone diagnostics are to be loaded.
5. Enter any requested passwords.
6. Follow any instructions to select a console.
7. Wait until the diagnostics load or the system appears to stop.
Did the diagnostics load?
NO
YES
Step 5
Starting at the top of the following table, find your symptom and follow the instructions
given in the Action column.
Symptom
The power LED does not come on, or comes
on and does not stay on.
The system appears to be stopped and NO
beep was heard from the system unit.
The system appears to be stopped and NO
beep was heard from the system unit. E122,
E123, or E124 is displayed on the operator
panel display.
The system appears to be stopped. A beep was
heard from the system unit.
The diagnostics are loaded and there was NO
beep heard from the system unit during the IPL
sequence.
The system stops with the Diagnostic Operating
Instructions displayed.
The diskette LED is blinking rapidly, or E1EA or
E1EB is displayed on the operator panel.
Go to "Step 5".
Go to "Step 6" on page 98.
Action
Check the power cable to the outlet. Check the
circuit breakers and check for power at the
outlet.
Ensure that the room temperature is within 60 -
90°F.
If you do not find a problem, record error code
M0PS0000 and report the problem to the
service organization.
Processor POST failure. Report error code
M0CPU000.
No good memory could be found. Report error
code M0MEM000.
No good memory could be found. Report error
code M0MEM001.
Record error code M0SPK001.
Go to "Step 6" on page 98.
The flash EPROM data is corrupted. Run the
recovery procedure for the flash EPROM.
Chapter 5. Hardware Problem Determination
95