Step 16
When you are loading the Standalone Diagnostics, the attributes for the terminal must
be set to match the defaults of the diagnostic programs. The ASCII terminal must be
attached to serial port 1 on the system unit.
Are you going to load Standalone Diagnostics and run them from a ASCII
terminal?
NO
YES
Step 17
This step loads the Standalone Diagnostics. If you are unable to load the diagnostics,
go to "Step 8" on page 89.
1. Turn on the power.
2. Insert the diagnostic CD-ROM into the CD-ROM drive.
3. When the keyboard indicator displays, press F5 on the directly attached keyboard,
or 5 on the ASCII keyboard, to indicate that standalone diagnostics are to be
loaded.
4. Enter any requested passwords.
5. Follow any instructions to select a console.
Did the Diagnostics Operating Instructions display without any obvious display
problem?
NO
YES
Step 18
The diagnostics did not find a hardware problem. If you still have a problem, contact
your software support center.
Go to "Step 17".
Be sure your terminal attributes are set to work with the diagnostic
programs.
Return to "Step 17" when you finish checking the attributes. Record
any settings that are changed.
Go to "Step 8" on page 89.
Go to "Step 10" on page 90.
Chapter 5. Hardware Problem Determination
93