Accuracy
Characteristics
8.3
Range
Atmospheric condi-
tions
Accuracy
Characteristics
Laser dot size
iCON robot 60/iCON builder 60, Technical Data
Accuracy refers to measurements to standard prisms.
EDM measuring
std. dev.
mode
ISO 17123-4,
standard prism
1 mm + 1.5 ppm
Single Manual
Continuous with
3 mm + 1.5 ppm
lock
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Principle:
Type:
Carrier wave:
Measuring system:

Distance Measurement without Reflectors

Reflector
CPR105 Flat prism (Reflective
tape)
CPR105 Flat prism (Cat-eye)
D:
Object in strong sunlight, severe heat shimmer
E:
Object in shade, sky overcast
F:
Underground, night and twilight
Standard measuring
0 m - 500 m
>500 m
Object in shade, sky overcast. Beam interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations of the specified accuracy. The
display resolution is 0.1 mm.
Type:
Carrier wave:
Measuring system:
Distance [m]
at 30
at 50
at 100
std. dev.
ISO 17123-4,
tape
3 mm + 2 ppm
3 mm + 2 ppm
Phase measurement
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Range D
[m]
[ft]
150
490
250
820
std. dev.
Measure time,
typical [s]
ISO 17123-4
2 mm + 2 ppm
3 - 6
4 mm + 2 ppm
3 - 6
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Laser dot size, approximately [mm]
7 x 10
8 x 20
16 x 25
Measurement
time, typical [s]
2.4
< 0.15
Range E
Range F
[m]
[ft]
[m]
170
560
170
250
820
250
Measure time,
maximum [s]
12
12
[ft]
560
820
53