Icon Robot 60/Icon Builder - Leica iCON robot 60 User Manual

Table of Contents

Advertisement

Recording
Laser plummet
Drives
Motorisation
Power
Internal battery
External battery
Environmental
specifications
iCON robot 60/iCON builder 60, Technical Data
Data can be recorded onto an SD card or into internal memory.
Type
SD card
Internal memory
Type:
Location:
Accuracy:
Diameter of laser point:
Type:
Maximum rotating speed:
External supply voltage:
Type:
Voltage:
Capacity:
Type:
Voltage:
Capacity:
Temperature
Type
All instruments
Leica SD cards
Battery internal
Bluetooth
Protection against water, dust and sand
Type
All instruments
Humidity
Type
All instruments
Capacity [MB]
• 1024
• 8192
• 1000
Visible red laser class 2
In standing axis of instrument
Deviation from plumb line:
1.5 mm (2 sigma) at 1.5 m instrument height
2.5 mm at 1.5 m instrument height
Endless horizontal and vertical drives
50 gon/s
Nominal voltage 12.8 V DC, Range 11.5 V-13.5 V
Li-Ion
7.4 V
GEB221: 4.4 Ah
GEB222: 6.0 Ah
NiMH
12 V
GEB171: 9.0 Ah
Operating temperature [°C] Storage temperature [°C]
-20 to +50
-40 to +80
-20 to +55
-30 to +60
Protection
IP55 (IEC 60529)
Protection
Max 95 % non condensing
The effects of condensation are to be effectively counter-
acted by periodically drying out the instrument.
Number of measurements
per MB
1750
1750
-40 to +70
-40 to +80
-40 to +70
-40 to +80
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon builder 60