Installer Settings

There are a number of 'Installer Settings' that should be set on
installation.
These can be found under the 'SET UP MENU' on page 13 of the

user instructions.

Clock Format
Daylight saving
Standby temperature
Upper and Lower
Temperature limits
TPI Cycles
Optimum Start
The TPI Cycles setting and Optimum Start settings should be
carefully set on installation as this will affect system performance.
AM/PM or 24 Hour clock display - Default
setting AM/PM
On or Off - Default setting ON
Frost protection setting – Default setting 5°C
Default settings 30°C and 5°C
This setting will change according to the
type of boiler being used - Default setting 6
For Gas boiler this setting should be 6
cycles per hour
For Oil boilers this setting should be 3
cycles per hour
For Electric panel heaters this should be 12
cycles per hour
On or Off – Default setting Off