Download Print this page

Secure SCS311 Installation Instructions Manual page 11

Wireless programmable room thermostat

Advertisement

Z-Wave Device Classes Implemented Device Class
Generic
Specific
Basic
Command Classes
Supported
Manufacturer specific
Version
Wake up (v2)
Thermostat set point (v2) Supports HEAT and AWAY HEATING HEAT.
Multilevel sensor
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_NOT_USED
BASIC_TYPE_CONTROLLER
Description
Secure Controls (UK) Ltd Manufacturer ID
Manufacturer ID = 0x0059
Product Type = 0x0004
Product ID = 0x0001
Provides the version number of the
application and the protocol stack used
Defines frequency, and to which node, the
unit will send Wake up notification. SCS311
or SCS317 remains awake for 10 seconds
after the last message, or until Wake up
notifications received.
Set, is mapped to the temporary (advance)
override. The sent set point will be applied
to the end of the current heating cycle.
Get, reports the current target temperature.
AWAY HEATING
Sets and reports the temperature for both
STANDBY and HOLIDAY modes.
Reports ambient temperature in ˚C or ˚F to
1 decimal place, and sends an unsolicited
message to gateway node in Association
Group 1 when temperature change by ∆T
11