Secure SCS311 Installation Instructions Manual page 15

Wireless programmable room thermostat

Advertisement

Command Classes
Controlled
Time
Thermostat mode
Application status
Basic
Note 1: Unless otherwise stated all command classes are version 1
Note 2: "The Delta T" is the change between temperature readings
required for the SCS311 or SCS317 to send temperature reports to the
Gateway node in Association Group 1. Setting this to its lowest value,
0.1˚C, will provide more frequent updates but at higher cost to the
battery.
Description
TIME and DATE GET request the
information from node associated to
Association Group 1 (the gateway node). If
not available the SCS311 or SCS317 will
rely on time entered locally.
Time and Date will be requested from the
gateway shortly after association or power
up and then once per day. Unsolicited TIME
and DATE REPORTS can be sent to the
SCS311 or SCS317 at any time.
Supports thermostat mode SET commands
(OFF or HEAT) to devices in Association
Group 2
When SCS311 or SCS317 cannot action or
respond to messages received, an
Application Rejected Request will be sent
as a response.
Basic SET commands will be sent to control
devices in Association Group 2 if they do
not support the appropriate modes in the
thermostat mode command class.
15