Binary switch
Thermostat operating
state
Battery level
Association
Set command
- 0x00, Cancel holiday mode
- 0xFF, Set holiday mode, starting
from today and lasts for 7 days, previously
stored holiday dates are over written
Get command
- 0xFF, Holiday mode is on/enabled
- 0x00, Holiday mode is off
Precise dates can only be set locally on
SCS311 or SCS317
Reports either call for heat (active) or idle
When SCS311 or SCS317 sends a control
message to the switch(es) in Association
Group 2 it will send and unsolicited
thermostat operating state report to the
gateway node in Association Group 1
Reports battery level as a %, levels below
20% will report a low battery warning to
gateway nodes in Association Group 1
Two association groups are supported
Group 1 - This node receives unsolicited
message from the following events
- Thermostat set point
- Thermostat operating state
- Schedule
- Multilevel sensor
- Battery
- Binary switch
Only one node can be associated to
Association Group 1.