VAR8 and Variants Operation, Commissioning, Fault Finding, and Maintenance Guide
21.2

Remote I/O Unit Digital Input as External Fault

To Program a Remote I/O Unit Digital Input as External Fault Input:
1. Select Remote I/O Unit's address on the RS485 bus.
Menu: Configuration System Router Ctrl Remote
The unit address should match the address set by a switch internal to the unit.
2. Select input and program it for 'External Fault'.
Menu: Configuration System Router Ctrl Remote Unit address <n> Digital In
3. Change fault description as required.
Menu: Configuration System Router Ctrl Remote Unit address <n> Digital In
Possible values: 18-character alphanumeric string
4. Any input that is not used should be configured as 'Not-Conf'.
Menu: Configuration System Router Ctrl Remote Unit address <n> Digital In
-