Problem Solving; Troubleshooting - Crestron CHV-TSTAT Operation And Installation Manual

Hide thumbs Also See for CHV-TSTAT:
Table of Contents

Advertisement

Thermostats
Sensor Setup Related Digital Joins (continued)
Signal Name
OMIT_LOC_HUM_F
OMIT_R1_HUM_F
OMIT_R2_HUM_F
R1_H_OUTDOOR_F
R2_H_OUTDOOR_F

Problem Solving

32 • Thermostats: CHV-TSTAT and CHV-THSTAT
Crestron CHV-TSTAT and CHV-THSTAT
Symbol
I/O
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output

Troubleshooting

The table below provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CHV-TSTAT/CHV-THSTAT Troubleshooting
TROUBLE
No display
No power from
system
Incorrect mounting to
backplate
Heating/Cooling
No power to
system not
thermostat
operating*
Thermostat minimum
off times operating
both systems
Indicator displays
Fan turns on when
Heat On, but no
furnace reaches
heat from register
setpoint
Cannot change
The upper or lower
temperature
temperature limits
setting
were reached.
Furnace cycles too
Anticipator setting
quickly
too low
High temperature
Anticipator setting
variance
too high
*H1, H2, C1, C2 may appear but the system will not activate until the 5 minute timer guards
have been satisfied.
Definition
Asserted when Omitting built in hum sensor (THSTAT)
Asserted when Omitting remote 1 humidity sensor
Asserted when Omitting remote 2 humidity sensor
Asserted when remote 1 humidity sensor is outdoor
Asserted when remote 2 humidity sensor is outdoor
POSSIBLE
CORRECTIVE ACTION
CAUSE(S)
Check for +24V on pins 24(C)
and 24(R)
Check thermostat mounting
Check circuit breaker
Check 24V connection at
thermostat and at furnace/air
conditioner
Recheck wiring connections
Wait 5 minutes
Wait five minutes, then recheck
registers.
Setpoint heat range is 38 – 90º F
(3-38º C).
Setpoint cool range is 59-100º F
(15 – 38º C)
Reprogram anticipator. Refer to
"Thermostat Setup" on page 14
Reprogram anticipator. Refer to
"Thermostat Setup" on page 14
Operations and Installation Guide – DOC. 8163

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chv-thstat

Table of Contents