Thermostats
HVAC Related Analog Joins (continued)
Signal Name
REGULATION_TEMP_F
BUILT_IN_TEMP_F
REM1_TEMP_F
REM2_TEMP_F
Indirect Text Joins (Serial)
Signal Name
MESSAGE
BUTTON_LABEL_1
BUTTON_LABEL_2
BUTTON_LABEL_3
BUTTON_LABEL_4
Advanced Setup Related Analog Joins
Signal Name
HEAT_ANTICIPATOR_F
COOL_ANTICIPATOR_F
AUTO_MODE_DEADBAND_F
HP_BALANCE_PT_F
AUX_BALANCE_PT_F
LCD_CONTRAST_F
TEMP_DISP_OFFSET_F
Setup Related Digital Joins
Signal Name
HEAT_COOL SYS_F
HEATPUMP_SYS_F
30 • Thermostats: CHV-TSTAT and CHV-THSTAT
Crestron CHV-TSTAT and CHV-THSTAT
Symbol
I/O
Both
Output
Advanced
Output
Advanced
Output
Advanced
Output
Symbol
I/O
Advanced
Input
Advanced
Input
Advanced
Input
Advanced
Input
Advanced
Input
Symbol
I/O
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output
Advanced
Output
Symbol
I/O
Advanced
Output
Advanced
Output
Definition
Temperature used for regulation, this is the mean
(averaged) temperature for all sensors declared "use", in
10ths of degrees
Temperature of the built-in sensor, in 10ths of degree,
Note that the values are reported regardless of the
use/OD/omit setting
Temperature of remote 1 sensor, in 10ths of degree
Unconnected sensors are reported as 0, Note that the
values are reported regardless of the use/OD/omit
setting
Temperature of remote 2 sensor, in 10ths of degree
Unconnected sensors are reported as 0, Note that the
values are reported regardless of the use/OD/omit
setting
Definition
Used for sending a message to the thermostat Appears
on the "messages" view screen
Provides the soft button label for the first remote function
button (up button, page 1)
Provides the soft button label for the second remote
function button (down button, page 1)
Provides the soft button label for the third remote
function button (up button, page 2)
Provides the soft button label for the fourth remote
function button (down button, page 2)
Definition
Heat anticipator value, 1-6 (refer to page 16)
Cooling anticipator value, 1-6 (refer to page 16)
Auto mode deadband value, 2-6 degrees (refer to page
16)
Heat pump balance point, 0-90˚F (refer to page 16)
Aux balance point, 0-90˚F (refer to page 16)
LCD contrast value, 1-10
Offset to be added to measured temperature value to
correct display to user preference, -6 - +6 degrees
Definition
Asserted when the system is heat/cool type (as opposed
to heat pump)
Asserted when system type is heat pump
Operations and Installation Guide – DOC. 8163