6.2.2 Separation Corona Wire Replacement

1. Remove the separation corona wire [C].
2. Hook the new separation corona wire on the terminal [D] of the right endblock.
NOTE: Make sure that the wire junction [E] is positioned inside the right
endblock.
3. Hook the other side of the separation corona wire on the spring hook [F]
(special tool: 54199653). While pushing the spring [G] in the direction of the
arrow, hook the separation corona wire on the spring.
4. Set the wire on the slots [H].

6.2.3 Transfer Corona Wire Replacement

1. Remove the transfer corona wire [I].
2. Install the new transfer corona wire.