Ricoh A163 Service Manual page 240

Hide thumbs Also See for A163:
Table of Contents

Advertisement

SERVICE TOOLS
Mode No.
Total Counter Unit
Setting
-2
Registration
Adjustment
-5
Toner Supply
Periods in Toner
-23
End Condition
Original Feed
Motor Speed
-24
Adjustment
-27 Factory Use Only
Length Size
Magnification
Compensation on
Leading Edge
-28
Registration
Adjustment for the
Rear Feed
-29
Synchro-cut
Length Auto
Adjustment
(297 mm)
-35
A251/A252
Function
Selects the unit in which the total counter
counts up by.
Adjusts the paper registration.
Selects the periods for supplying toner after
clearing the toner end condition.
Adjusts the speed of the original feed motor
(A252 copier only).
The fusing roller's speed is slightly higher
than the drum speed.
The speed of the copy paper transport will
slightly increase after the leading edge of
the copy paper enters the fusing unit.
To compensate for this, the speed of the
original feed motor is corrected from the
leading edge to 183 mm (A252 copier only).
Adjust the paper registration for the rear
original feed (A252 only).
If the setting of SP#-74 is 1, this setting is
used for the paper registration for the front
original feed as well as the rear original
feed. In this case, this adjustment is added
to the SP#-5 adjustment.
Adjusts the original cut length in Synchro
Cut mode at 297 mm (standard length).
Insert the 297 mm length original five times
(this number displayed on the copy number
indicator can be changed : 1 to 10). If the
actual original length is different from the
standard length, input the following value in
the cut length indicator before inserting the
original:
Actual Length - Standard Length
Then the machine automatically calculates
the correction value. The data is overwritten
on SP#-38.
4-6
Data
0: 1 yard
1: 1 m
2: 100 inches
3: 50 inches
4: A1 length (594 mm)
5: Sheet (Any size)
6: 1 foot
0: Standard
–9.9 ← 0 → 9.9 mm
Advance
Delay
0: 60 s
1: 70 s
2: 80 s
3: 90 s
-50 (Faster) ← 0 → 50
(Slower)
0.025 %/step
-100 ← 10 → 100
(Shorter)
(Longer)
–2.5%
+2.5%
0: Standard
–9.9 ← 0 → 9.9 mm
Advance
Delay
-9.9 ← 0 → 9.9
1 step = 0.1 mm