INSTALLATION PROCEDURE
[A]
[G]
[E]
[F]
3. Open the paper path section [A].
4. Remove the right upper cover [B] (2 screws).
5. Remove the drum protection sheet [C] and remove the screw [D] to apply
cleaning blade pressure to the drum.
6. Open the fusing exit section. Remove the two strips of shipping tape [E] and
protection sheet [F].
7. Remove two strips of shipping tape [G]. (Close the paper path section and
fusing exit section.)
A251/A252
A252I501.WMF
[E]
3-6
[B]
[C]
[D]
A252I502.WMF
A252I510.WMF
SM