SERVICE TOOLS
Mode No.
Hot Roller
Temperature
-7
Adjustment
Pressure Roller
Temperature
-8
Adjustment
Hot Roller/
Pressure Roller
Temperature
Display
-9
Drum Charge
Setting
-10
Copy Grid Setting
-11
Transfer Corona
Voltage Setting
-12
Transfer Voltage at
the Paper's Trailing
Edge
-13
B047/B048
Function
Change the hot roller temperature
setting.
Change the pressure roller
temperature setting.
Displays the hot roller temperature and
pressure roller temperature.
Even after the SP mode is canceled,
the temperature will be displayed
during the copy cycle and in standby
mode
To stop this, turn the main switch off
and on.
Determines the drum charge voltage.
In this mode, the charge corona can be
turned on and off using the Copy
Media key.
Translucent paper = ON
Translucent Film = OFF
Determines the copy grid voltage.
In this mode, the grid voltage can be
turned on and off using the Copy
Media key.
Translucent paper = ON
Translucent Film = OFF
Determines the transfer corona
voltage.
In this mode, the transfer corona can
be turned on and off using the Copy
Media key.
Translucent paper = ON
Translucent Film = OFF
To facilitate setting SP modes, when
SP#-12 is entered, SP#-13 will be
automatically set to (SP#-12's value X
1.5)
Determines the transfer corona voltage
at the paper trailing edge.
In this mode, the transfer corona can
be turned on and off using the Copy
Media key.
Translucent paper = ON
Translucent Film = OFF
4-14
Data
0: Standard
–9 ← 0 → 9°C
Decrease Increase
0: Standard
–9 ← 0 → 9°C
Decrease Increase
Fu = XXX
Pr = XXX
Fu: Hot roller
temperature
Pr: Pressure roller
temperature
If the hot roller
temperature is lower than
80°C (pressure roller
temperature is lower than
50°C), "LLL" is displayed.
If the hot roller
temperature is higher than
220°C (pressure roller
temperature is higher than
180°C), "HHH" is
displayed.
200: Standard
150 ← 200 → 249
Low
High
9: Standard
0 ← 13 → 15
Low
High
80: Standard
40 ← 80 → 120
Low
High
120: Standard
40 ← 120 → 249
Low
High