5.
FUSING
5.1
FUSING UNIT REMOVAL
[H]
[E]
[B]
1. Remove the copier rear cover.
2. Open the exit cover [A] and remove the shoulder screws [B] at both ends.
3. Disconnect the connector [C] and flex the hinge arms [D] of the exit cover
slightly to the outside of the exit unit shafts and remove.
4. Turn the exit unit 1/4 of a turn to the front side (rear view) and remove it by
pulling out.
NOTE: When reinstalling the exit unit, set the right hinge [F] between the two
pulleys [G] and raise the left hinge [H] using tape [I].