For hot water heaters with thermostatic valves, the
Comfort temperature can be provided by adjusting the
thermostat of each radiator.
In this case, only Economy and Frost Protection tem-
peratures are set by the RADIO TYBOX.
Comfort temperature set by the
TYBOX (by default)
Controlling the
Comfort temperature controlled by
Comfort
each radiator or fan coil unit.
temperature
Here, the display reads ConF
during Comfort period.
Anti-seizing disabled (default)
Circulator
Anti-seizing enabled
anti-seizing
(circulator operates for 1 minute
every 24 hours)
- 18 -
Advanced configurations (menu 2)
2
Press button
.
To change the various settings, press the + or - but-
tons, then press OK to confirm the change and go to
the next setting.
Program and temperature settings
(from 5 to 30°C) modification authorized
Modification
authorization
Program and set-point setting
for the user
modification unauthorized
(Heat comfort: 16 to 22°C,
Cool comfort: 21 to 27°C,
Warm economy: 13 to 19°C,
Cool economy: 24 to 30°C)
If there is a difference between the temperature noted
(thermometer) and the temperature measured and
displayed by the unit, function 2-02 modifies the way
the probe takes measurements so as to compensate
for this difference.