Choice of heat pump type
1-06
0 = reversible heat pump (by default)
1 = Non-reversible heat pump (heat only)
Controlling the Comfort temperature
0 = set by the RADIO TYBOX (by default)
1-08
1 = by each radiator or fan coil unit.
Circulator anti-seizing feature
1-09
0 = Disabled
1 = Enabled
Modification authorization
0 = Program and settings may be changed
2-01
1 = Program not modifiable and set-point temperature
settings limited (Comfort: 16 to 22°C
Economy: 13 to 19°C, Frost Protection: 5 to 11°C)
Correction of the temperature measured
2-02
by -5°C to +5°C in increments of 0.1°C.
Automatic mode temperature display option
2-04
0 = Set-point temperature display
1 = Room temperature display
Control time base
2-08
30 Minutes
45 Minutes
Selection of the opening direction for the
change-over relay
2-09
0 = Closed in cool mode
1 = Closed in heat mode
- 32 -
60 Minutes
Summary table of configurations
Radio association (menu R)
Home automation features
r-01
0 = No
Consumption indication
r-02
0 = No
rAd
Radio products association
Zone
Reserved menu
rAd 1
With a RADIO TYWATT
Number of CTs
3-12
0 = No RADIO TYWATT 1 = 1 CT (Heating)
2 = 2 CTs (Heating + DHW) 3 = 3 CTs
3-13
to
Cost per kWh according to subscription
3-18
- 33 -
1 = Yes
1 = Yes