Reversible heat pump thermostat
+ change-over
230 V
1 2
Power supply
230 V
Heat pump relay
common contacts
- Menu configuration
Choice of heat pump type
1-06
0 = Heat cool reversible heat pump (by default)
Selection of the opening direction for the
2-09
change-over relay
0 = Closed in cool mode - 1 = Closed in heat mode
- Description of the operating LEDs
LED is lit up if heat
mode is enabled
LED is lit up if "On"
is requested
The receiver is associated with the RADIO TYBOX 802 in
mode 1 by default (see radio association/ menu R section)
Mode 1
RF 652
Com
S2
Thermostat
S1
input
3 4 5
Change-over input
HEAT
ON
RF 652
- 12 -
Reversible heat pump with
2 thermostat inputs (cool / heat)
For this type of use, the receiver must be set to
mode 2 before wiring the heat pump's heat and cool
inputs on the thermostat.
To change the mode on your receiver:
-
turn the knob to
,
i
- Press the
button to display the
temperature
i
- then press the
button for 5
seconds.
Pressing the receiver button switches between mode 1
and 2. Let the HEAT LED flash rapidly.
The HEAT LED flashes slowly: Mode 1
The HEAT LED flashes rapidly: Mode 2.
Mode 2
RF 652
HEAT
ON
RF 652
Choose mode 2
- 13 -
5 sec.