Fitting the thermostat • Remove the protective tab from the batteries. ➊ We recommend that you install your device: • Open the thermostat housing by pressing on clip - where there is easy access, such as a corridor, living room or entrance hall, •...
Connections Fitting the batteries • Insert 2 LR03 1.5 V alkaline Connecting a boiler with thermostat input batteries, making sure to • Connect receiver terminals 1 and 3 to both termi- respect the battery polari- nals of the boiler thermostat input. Example of a boiler ties.
Connecting a boiler without thermostat Controlling electric convectors Controlling a heat pump input To control electrical convectors, you MUST Heat pump Heat pump Heat pump If the boiler does not have a thermostat use a power contact switch that is suitable with thermostat input with thermostat heat input with thermostat input...
Activation Configuration To access the configuration menus, turn the knob to the position marked The day numbers flash. Turn the knob to the position Days (1: Monday… 7: Sunday) • Press + or - to set the day, then OK to confirm and go to the next setting.
Correcting the temperature measured Automatic mode temperature display option IMPORTANT: In order to change this setting, the unit has to have been running for at CF02 Continuous set-point temperature display (by default). least 2 hours beforehand. With this option, press i to display the room temperature. CF0 1 Correction possible from -4°C to + 4°C in increments of 0.1°C.
Circulator anti-seizing With thermostatic valve electric heating or hot water heaters, the Comfort temperature can be provided by adjusting the thermostat of each radiator. In this case, only the Economy If your thermostat controls a circulator, set the value of the CF05 menu to equal 1. and Frost Protection temperatures are set by the TYBOX.
Restoring factory settings Summary table of configurations You can execute a general reset command to return to the factory settings: Correction of the temperature measured - the default configuration settings CF01 by -4°C to +4°C in increments of 0.1°C (0 by default). - the default set-point temperatures, Heating Mode - Comfort: 19°C, Economy: 16°C Cooling mode - Comfort: 23°C, Economy: 28°C Automatic mode temperature display option...
Notes Technical features • Power supplied by two LR03 or AAA 1.5 V alkaline batteries. “No rechargeable batteries” • 1 2A / 230V power outlet • Dimensions: 111 x 84 x 28.5 mm • Protection rating: IP 30 • Installation in an environment with normal pollution levels •...