DELTA DORE TYBOX 610 Installation Manual

DELTA DORE TYBOX 610 Installation Manual

Weekly programmable thermostat
Hide thumbs Also See for TYBOX 610:

Advertisement

DELTA DORE - Bonnemain
35270 COMBOURG - FRANCE
E-mail: deltadore@deltadore.com
This appliance is compliant with the requirements of
directives 2004/108/EC (Electromagnetic Compatibility)
and 2006/95/EC (Low-Voltage Safety)
Because of changes in standards and equipment, the characteristics given in the text and the
illustrations provided in this document are not binding unless expressly confirmed
TYBOX 610
Weekly programmable thermostat
Installation guide
1234567
i
0h
0h
2
2
4
4
6
6
8
8
TYBOX
10 12 14 16 18 20 22 24
10 12 14 16 18 20 22 24
AUTO
AUTO
O
PROG
PROG

Advertisement

Table of Contents
loading

Summary of Contents for DELTA DORE TYBOX 610

  • Page 1 TYBOX 610 Weekly programmable thermostat Installation guide DELTA DORE - Bonnemain 1234567 35270 COMBOURG - FRANCE E-mail: deltadore@deltadore.com 10 12 14 16 18 20 22 24 10 12 14 16 18 20 22 24 AUTO AUTO This appliance is compliant with the requirements of...
  • Page 2: Table Of Contents

    Warnings Contents Fitting the thermostat ..........•...
  • Page 3: Fitting The Thermostat

    Fitting the thermostat • Remove the protective tab from the batteries. ➊ We recommend that you install your device: • Open the thermostat housing by pressing on clip - where there is easy access, such as a corridor, living room or entrance hall, •...
  • Page 4: Connections

    Connections Fitting the batteries • Insert 2 LR03 1.5 V alkaline Connecting a boiler with thermostat input batteries, making sure to • Connect receiver terminals 1 and 3 to both termi- respect the battery polari- nals of the boiler thermostat input. Example of a boiler ties.
  • Page 5: Connecting A Boiler Without Thermostat Input

    Connecting a boiler without thermostat Controlling electric convectors Controlling a heat pump input To control electrical convectors, you MUST Heat pump Heat pump Heat pump If the boiler does not have a thermostat use a power contact switch that is suitable with thermostat input with thermostat heat input with thermostat input...
  • Page 6: Activation

    Activation Configuration To access the configuration menus, turn the knob to the position marked The day numbers flash. Turn the knob to the position Days (1: Monday… 7: Sunday) • Press + or - to set the day, then OK to confirm and go to the next setting.
  • Page 7: Correcting The Temperature Measured

    Correcting the temperature measured Automatic mode temperature display option IMPORTANT: In order to change this setting, the unit has to have been running for at CF02 Continuous set-point temperature display (by default). least 2 hours beforehand. With this option, press i to display the room temperature. CF0 1 Correction possible from -4°C to + 4°C in increments of 0.1°C.
  • Page 8: Air Conditioning Function

    Circulator anti-seizing With thermostatic valve electric heating or hot water heaters, the Comfort temperature can be provided by adjusting the thermostat of each radiator. In this case, only the Economy If your thermostat controls a circulator, set the value of the CF05 menu to equal 1. and Frost Protection temperatures are set by the TYBOX.
  • Page 9: Restoring Factory Settings

    Restoring factory settings Summary table of configurations You can execute a general reset command to return to the factory settings: Correction of the temperature measured - the default configuration settings CF01 by -4°C to +4°C in increments of 0.1°C (0 by default). - the default set-point temperatures, Heating Mode - Comfort: 19°C, Economy: 16°C Cooling mode - Comfort: 23°C, Economy: 28°C Automatic mode temperature display option...
  • Page 10: Technical Features

    Notes Technical features • Power supplied by two LR03 or AAA 1.5 V alkaline batteries. “No rechargeable batteries” • 1 2A / 230V power outlet • Dimensions: 111 x 84 x 28.5 mm • Protection rating: IP 30 • Installation in an environment with normal pollution levels •...