Page 2
COMPOSITION Your PACK comprises: - 1 TYBOX 5000 connected room unit - 1 TYDOM 1.0 home automation and its connector CHAUFFAGE SALON .0 °C .4 °C mesurée...
(HP) no-reversible 3/ Mounting 4/ Installation 5/ Wireless association 6/ Configuration 7/ Troubleshooting 7.1 Signals and possible faults on the wireless room thermostat TYBOX 5000 7.2 Signals and possible faults on the TYDOM 1.0 8/ Technical characteristics...
1/ LOCATION Since the temperature measurement sensor is inside the box, you must install the thermostat flush-mounting box: - on an accessible wall at a height of 1.50 m - away from heat sources (fireplaces, sunlight) and draughts (windows, doors) IMPORTANT: Do not install the thermostat on a wall in contact with the outdoors or with an unheated room (e.g. garage, etc.) The sleeve output in the flush- mounting box must be blanked off (with mastic) in order to avoid unwanted air movements that could bias the sensor reading.
(directive 89/336/EEC). 2A max. / 230V~ 2.1 Circulator control Circulator 2A max. / 230V~ 2A max. / 230V~ TYBOX 5000 2.2 Control of the thermostat input of the boiler or heat pump (HP) no-reversible 2A max. / 230V~ Boiler Thermostat Thermostat...
Page 6
2/ CONNECTION ❶ Remove the terminal, on the back of the device, using a screwdriver. ❷ Connect the terminal to the control wire (circulator, boiler or heat pump thermostat input). ❸ Fit the terminal back into its position.
3/ MOUNTING ❶ Remove the thermostat cover by pushing the pin using a screwdriver. ❷ Attach the base by using suitable fixings for mounting. Fit the cover back onto the thermostat. ❸ Insert the batteries, with the right polarity Click 2 x 1,5V - AAA LR03 Click...
F. Not used G. Mains adaptor socket H. Configuration/Information button I. Connected TYBOX 5000 Connect your TYDOM 1.0 depending on your installation. TYDOM 1.0 must be installed near your ADSL box line. ❶ Connect TYDOM 1.0 to the box with the Ethernet cable.
5/ WIRELESS ASSOCIATION Associate the TYDOM application with the connected TYBOX 5000 100% 100% 19:41 19:41 19:41 100% 19:41 100% Carrier Carrier 9:41 AM 9:41 AM Carrier Carrier 100% 100% 9:41 AM 9:41 AM 100% 100% Carrier Carrier 9:41 AM...
Page 11
TYBOX 5000 Garage Gate Press 3 secon Alarm On the "mo Consommation Cameras TO AS Others ❺ Select 'Hydraulic' ❻ Swipe your finger over the screen t o select 'TYBOX 5000' 100% Carrier 9:41 AM 100% evices HEATING Carrier 9:41 AM 100% Carrier GROUPS TOTAL HEATING...
6/ CONFIGURATION This menu is used to determine all the settings adapted to your installation. ❶To enter configuration mode, press the MODE button for 10 seconds until the screen displays CF01. ❷Press + or - to set. ❸Briefly press MODE to go to the next menu. Press MODE or wait 5 seconds to exit. CF01 - Correcting the temperature measured Setting from -5°C to +5°C Example: If the temperature displayed by the unit is 15°C and the actual...
Page 13
CF05 - Type of temperature displayed in AUTO mode Temperature setting display (default selection) Display of the measured room temperature. 1: Pressing the + or - button once displays and sets the temperature setting (in ON mode). CF06 - Regulation time base 15 minutes (default settings) 30 minutes 45 minutes...
Page 14
❶ Press the + and MODE buttons simultaneously until the screen shows for example rF00. ❷ On the door/window magnetic contact, press the button. ❸ Check that the screen evolved and shows rF01 on TYBOX 5000. mode mode mode / + mode / + >...
7/ TROUBLESHOOTING 7.1 Signals and possible faults on the wireless room thermostat TYBOX 5000 • When you press a button, the screen displays: ____ Access to the settings is locked. To unlock, press and hold the + and - buttons for 10 seconds.
7/ TROUBLESHOOTING 7.2 Signals and possible faults on the TYDOM 1.0 System status Green and System accessible locally and remotely, user logged in flashing Green on and System accessible locally and remotely steady Orange and System accessible locally, user logged in flashing Orange and System accessible locally...
Page 17
Advanced functions Fixed DHCP/IP Press the button for at least 3 seconds Action Magenta and flashing Release the button (within 15 seconds) (slowly) It is advised to use the TYDOM application to access this function. Delete password Press the button for at least 15 seconds Action Magenta and flashing ...
8/ TECHNICAL CHARACTERISTICS Wireless room thermostat TYBOX 5000 • Contact output 2A (230V) • Ball test: 125 ° C • Rated surge voltage: 4000V • Powered by 2 lithium batteries 1.5 V, LR03/AAA (supplied) • Class III insulation • Radio frequency 868.7 MHz to 869.2 MHz • Maximum wireless power: <10 mW •...
Page 19
TYDOM 1.0 home automation box • Main power supply 100 V~/240 V~, +/-10%, 50/60 Hz 0,3A, 1,0 A OUTPUT : 5V • Radio frequency 868.7 MHz to 869.2 MHz • Maximum wireless power: <10 mW • Wireless range: 100 to 300 metres outside, variable depending on the associated equipment (the range can vary depending on the installation conditions and the electromagnetic environment) •...