8. The display now reads: "AUTO CUT ?; Y=CASH N=CLEAR".
9. The display now reads: "SERVICE MODE; CLOSED". The RAM Clear procedure

ER-925/ER-945 Memory All Clear

1. Turn the power switch located on the right side of the register to the OFF position.
2. Turn the control lock to the S position.
3. Press and hold the key position where the CHECK key is located on the default
4. Continue to hold the SUBTOTAL key while turning the power switch to the ON
5. Press the upper left key of the keyboard, then the lower left key, then the upper right
Note: In the default configuration, there are 21 double-width PLU keys. Under each
key, the left-most key is inactive and the right-most key is active. The four-key sequence
shown with the default configuration will set the keyboard in the default 21-PLU key
configuration. When the keyboard is expanded, the four-key sequence shown will set
the keyboard in the expanded configuration.
If you wish to build a custom configuration, you will want to perform a memory clear
for the expanded configuration, and then assign each key position individually.
6. After a short delay, the printer will display the message: "Please Wait...". Memory is
SAM4s ER-900 Series Operator's & Programming Manual v.1.28
Press CLEAR.
is complete.
keyboard layout:
position. The message "RAM ALL CLEAR" displays.
key, and finally press the lower right key.
1
2
1
2
ER-925 and ER-945
Press and hold the
SUBTOTAL key position
during power-up in S mode.
3
4
3
4
ER-925/ER-945
Default
Configuration
(21 PLU Keys)
ER-925/ER-945
Expanded
(63 PLU keys)
Getting Started • 27