Programming Instructions

?
Press
,
User Access Code
The
rm and Part- rm LEDs will illuminate and all
Zone, Fire and tamper LEDs will flash.
The system is now in Programme Mode
Note:
fter programming all required functions press
to leave Programme mode and return to Standby.
ESC

User ccess Code

Default setting: 1 2 3 4
1
Press
Zone LEDs 1-4 will illuminate.
Enter a new 4 digit User ccess code.
entered an illuminated zone LEDs will be turned OFF.
Press
to save the new User ccess code and
return to programming mode.
Press
to return to programming mode without
ESC
saving.

System House Code

2
Press
The Zone LEDs 1-6, Fire and Tamper LEDs will
illuminate to display the current House Code setting
with an illuminated LED indicating a setting of "on" in
the House Code.
For example:
house code of 11110010, will be
indicated with zone LEDs 1-4 ON and 5-6 OFF, Fire
LED ON and Tamper LED OFF.
a)
t the Control Panel:
By pressing buttons 1-8 on the Control Panel,
setting the status LEDs so that they indicate the
required house code setting. The LEDs will switch to
the opposite state each time the button is pressed.
LED ON = (House Code DIP Switch On)
LED OFF = (House Code DIP Switch Off)
Press
to save the new setting and return
to programming
Press
to return to programming mode
ESC
without saving.
?
?
?
,
s each digit is
b) Using a Remote Control:
With the required House Code already set in the
remote, press the DIS RM button on the Remote
Control.
The Control Panel will beep twice to acknowledge
the signal.
The Zone, Fire and Tamper LED status will be
updated to correspond with the House Code set on
the Remote Control and now programmed into the
Control Panel.
Press
to return to programming mode.

Instant Delay Zones

Default setting: Zone 1
Zones 2-6
3
Press
The zone LEDs corresponding to the zones currently
set to Delay will be illuminated. LEDs for zones set to
Instant will be OFF.
LED ON
Delay Zone
LED OFF
Instant Zone
To change the settings of a zone press the button
corresponding to the zone number. The zones will switch
to the opposite mode each time the button is pressed.
Press
to save the new setting and return to
programming mode.
Press
to return to programming mode without
ESC
saving.
Entry / Exit Delay
Default setting: 30 seconds
4
Press
The zone LED corresponding to the current setting
will illuminate.
0
no delay, (i.e. Instant)
1
10 seconds
2
20 seconds
3
30 seconds
4
40 seconds
5
50 seconds
19
Delay
Instant