TESTING THE SYSTEM

INITIAL TESTING

As the system is initially installed it is recommended
that each device is tested in turn as it is installed, (refer
to testing instructions for particular device).

TESTING AN INSTALLED SYSTEM

1. Before commencing testing please ensure the
following conditions apply:
- The system is in Operating mode and Disarmed
- There is no movement in any PIR protected area.
- All doors/windows protected by Magnetic Contact
Detectors are closed.
- All battery covers and housings are correctly
fitted.
2. Arm the system by pressing the 'INSTANT-ARM'
button on the Remote Control.
acknowledge the signal by beeping once, (unless
Beep Disable has been selected).
3. After 45 seconds walk into an area protected
by a PIR Movement Detector and ensure that
a Full Alarm condition is initiated, (i.e. the Siren
sounds).
4. Stop the Siren and Disarm the system by pressing
the 'DISARM' button on the Remote Control.
5. Continue to test the all PIR Movement Detectors in
turn as described above, (steps 2 - 4). Remember
that the detectors need to settle for at least 40
seconds between each activation.
6. Arm the system by pressing the 'INSTANT-ARM'
button on the Remote Control.
7. Open a door/window protected by a Magnetic
Contact Detector and ensure that a Full Alarm
condition is initiated.
8. Stop the Siren and Disarm the system by pressing
the 'DISARM' button on the Remote Control.
9. Test each Magnetic Contact Detector in turn as
described above, (steps 6 - 8).
10. Arm the system by entering the User Access code
followed by the 'INSTANT-ARM' button on the
Remote Keypad.
11. Press and hold both 'DELAY-ARM' buttons on the
Keypad for approx 2-3 seconds and ensure that a
Full Alarm condition is initiated.
14
12. Stop the Siren and Disarm the system by entering
OPERATING
INSTRUCTIONS

SYSTEM SERVICE MODE

To prevent a Full Alarm condition from being initiated
when either opening the Solar Siren or replacing a
battery, it is necessary to first put the system to
Service mode by pressing and holding the 'DISARM'
The Siren will
button on the remote control for approximately
10 seconds. The Siren will acknowledge the signal
by beeping twice followed by one long beep after 10
seconds, the 'DISARM' button can then be released.
When you have completed any alterations to the
system turn the system back to Operating Mode.

SYSTEM OPERATING MODE

To put the system back into Operating Mode press
and hold the 'INSTANT-ARM' button on the Remote
Control for approximately 10 seconds until the
Siren acknowledges the signal by emitting one long
beep. The system will be in Operating mode in a
Disarmed state.
Note: The 'INSTANT-ARM' button should be released
during or immediately after the long beep, otherwise
the system will switch into an Armed state.

ARMING THE SYSTEM

When leaving the premises, the system must be armed.
However, before doing so, check that all windows are
closed and locked, all protected doors are closed and
PIR Movement Detectors are not obstructed. Ensure
that pets are restricted to areas not protected by PIR
Movement Detectors.
The system has two Armed modes, Instant and Delay.
Instant mode will immediately set the system into a
fully armed state. Any activation of a Detector will
the User Access code followed by the DISARM
button on the Keypad.
Note: It is recommended that the system is tested
at regular intervals, (every 3 months), to ensure that
all elements of the system are operating correctly.