Hard-Wired Solar Siren Test

2
Press
The internal relay driving the hardwired siren will be
switched ON for a period of approximately 5 seconds.
Zone LED 2 will be illuminated during the test.

Solar Siren Test

3
Press
The Control Panel alarm and the External Solar Siren
will be operated for a period of approximately
5 seconds with the external Solar Siren switching ON
and OFF a few seconds after the Control Panel.
Zone LED 3 will be illuminated during the test.

Control Panel LED Test

4
Press
Zone LED 4 will illuminate.
Use
and
illuminate each LED in turn.
Press
to exit LED
ESC

Voice Dialler Test

6
Press
Zone LED 6 will illuminate.
The voice dialler will call each activate number in the
dialling sequence in turn. When a call is answered the
pre-recorded alarm message will be replayed. If the
call is unanswered or an acknowledgement signal is not
received from the number called, (i.e. by pressing the
button on the telephone keypad) the next number in the
sequence will be called.
Press
to exit voice dialer test.
ESC
buttons to scroll through and

Factory Defaults

User ccess Code
larm Duration
Hardwired Siren
Zone Operating Mode
Part- rm
Instant/Delay
Entry/Exit Delay
Entry/Exit Warning Tone
Zone Lockout
Jamming Detection
Phone Numbers
Message Play Time
larm Message
Call Routing
Call ttempts
Dial Method

Reset Factory Default Conditions

1. Press
,
to place the system in Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
3. Switch OFF the mains supply to the plug-in PSU
daptor.
4. Remove either back-up battery and disconnect the
battery leads.
5. Set jumper link P1 to the ON position.
6. Reconnect the battery leads and replace the back-
up battery in position.
7. The Control Panel will now set itself with all factory
default settings. This takes approx. 10 seconds.
8. Reconnect and switch On the supply to the PSU
adaptor.
9. Reset jumper link P1 into the OFF position.
10. Close the Control Panel cover and refit the fixing
screws.
18
1 2 3 4
3 minutes
Equal to larm Duration
Zones 1-6: Intruder
Zones 1: Disabled
Zones 2,3,4,5,6:
Zone 1: Delay
Zones 2-6: Instant
30s
On
On
Off
Not programmed
70s
Not programmed
ll numbers disabled
3
Tone/DTMF
?
?
?
?
User Access Code
ctive
,