Entry / Exit Warning Tone
Default setting: ON
8
Press
The zone 1 LED will illuminate to indicate the current
status of the Entry/Exit warning tone.
LED ON
Tone enabled
LED OFF
Tone disabled
1
Press
to change the setting to the opposite
state.
Press
to save the new setting and return to
programming mode.
Press
to return to programming mode without
ESC
saving.

Jamming Detection

This feature controls the Control Panels RF jamming
detection circuitry, which if enabled, will continuously
scan for radio jamming signals on the system
operating frequency.
Default setting: OFF
9
Press
The zone 1 LED will illuminate to indicate the current
Jamming Detector status.
LED ON
Jamming Detection enabled
LED OFF
Jamming Detection disabled
1
Press
to change the setting to the opposite
state.
Press
to save the new setting and return to
programming mode.
Press
to return to programming mode without
ESC
saving.
Note: The jamming detection program setting will
only control the jamming detection feature in the
Control Panel.

Hard-Wired Siren

Default setting: equal to larm Duration
1
0
Press
The zone LED corresponding to the current setting
will illuminate.
0
2 seconds
1
30 seconds
2
1 minute
3
3 minutes
4
5 minutes
5
equal to larm Duration
Press the key corresponding to the required Hardwired
output activation period, the corresponding zone LED
will illuminate as the setting is changed.
Press
to save the new setting and return to
programming mode.
Press
to return to programming mode without
ESC
saving.

Zone Operating Modes

Each alarm zone may be programmed to operate in
one of 5 different modes depending on the type of
alarm function it is required to perform.
Panic larm
- used to provide 24 hour monitoring of any Panic
Switch fitted to the system.
Switch will immediately initiate a Full larm condition.
24 Hour Intruder
- used to provide 24 hour monitoring of areas
requiring continuous security protection even while
the system is Disarmed, (e.g. gun cabinet, safe
etc).
ctivation of any Detector on a security zone
will immediately initiate a Full larm condition.
Fire
- used to provide 24 hour monitoring of any
Fire/Smoke Detectors fitted to the system.
ctivation of any Detector will immediately initiate
a Full larm condition.
Test
- when the system is armed, any Detector on the zone
will cause the appropriate zone LED on the Control
Panel to flash without initiating a Full larm condition.
21