Setting The Solar Siren Transmitter Module; Operating Instructions - Response Protector P500S Installation & Operating Manual

Solar wirefree alarm system
Table of Contents

Advertisement

The installation of your Solar Siren is now complete.
Note: Once the batteries have been connected, the
Unit will be operational and it is important that the Solar
Panel receives sufficient light to maintain the battery
charge. Also, the Unit should not be repeatedly set into
alarm during installation/testing as this could rapidly
drain the battery.
SETTING THE SOLAR
SIREN TRANSMITTER
MODULE
A small radio transmitter is incorporated within the
Control Unit to operate and control the external Solar
Siren.
To set the transmitter and operate the Solar Siren
proceed as follows:
1. Turn the Control Unit 'OFF' by entering
?
?
?
Access Code
at the Control Unit keypad.
indicator light will extinguish.
2. With the Control Unit in 'OFF' mode, undo the
cover retaining screws and hinge the Control Unit
front cover down.
3. Set the miniature dip switches 1-8 on the Siren
transmitter module (at the bottom of the Control
Unit) to the same sequence of 'ON's and 'OFF's as
set in the Solar Siren (the "Siren Code").
DO NOT SET TO THE "HOUSE CODE" USED IN
THE DETECTORS
4. Close the Control Unit front cover and secure the
two retaining screws.
5. Turn the Control back 'ON' by entering
?
?
?
Access Code
at the Control Unit keypad.
Note: Once the system has been installed, setting the
Control Unit to the 'Test Mode' will prevent the external
Siren from activating during testing. This will allow you
to test the system without causing unnecessary
disturbance.
Protector P500S
?
The green Power
?
1
N.O.
2
C
3
N.C.
4
POWER (–)
5
POWER (+)
RED
6
SIREN
BLACK
7
COM
YELLOW
8
CHARGE
9
TAMPER
ON
1
2
3
4
5
6
7
8
Siren Code
Solar Siren
Transmitter Module
OPERATING
INSTRUCTIONS
FULLY ARMING THE SYSTEM
When leaving the premises, the system must be Fully
Armed.
However, before doing so, check that all
windows are closed and locked, all protected doors
are closed, and Passive Infra-Red Detectors are not
obstructed. Ensure that pets are restricted to areas
not protected by Passive Infra-Red Detectors, or that
suitable precautions have been taken to allow for pets.
To Fully Arm the system, hinge open the keypad cover,
?
?
and enter
Access Code
then close the keypad cover. If the system exit tone has
been set for 'continuous' the Control Unit Sounder will
emit a continuous tone for the duration of the preset exit
time, arming automatically when the exit time expires.
If the system exit tone has been set for 'Semi Silent',
the control unit sounder will emit two short bleep
tones when the
button is pressed and two short
bleep tones on expiry of the exit time.
All occupants must leave the premises before the exit
time has expired. If for any reason you are unable to
leave the premises before the exit time has expired,
you will need to Disarm the system, then re-arm.
Failure to do so will cause a Full Alarm if any protected
door is opened or movement is detected by a Passive
Infra-Red Detector.
Note: When Fully Armed, the Control Unit top green
light will be constantly illuminated. (Refer to page 3).
?
?
on the keypad
13