Basic Options

Setting Scale Options

There are several options you can set with your scale such as zero-
ing the weight on the scale, turning the scale on/off, viewing metric
weights, and saving/changing class or ZIP settings when weight
changes on your scale. Most of the scale options are accessed by
pressing the selection key next to SCALE: line at the Home screen.
The Scale Options menu choices are:
SCALE OPTIONS
◄Zero the scale
◄Turn Scale OFF
◄View metric weight
WHEN WEIGHT CHANGES
◄Change/Retain class
◄Change/Retain ZIP
Zeroing the Scale
You can reset the scale to zero to lessen the chance of accidentally
printing the wrong postage.
At a Using PC Meter Connect™
Select the My Meter tab, then click Reset Scale To Zero. A "Scale
Has Been Recalibrated" message displays.
At Mailing Machine
1. At the Home screen, press the selection key next to SCALE: line.
2. Select "Zero the scale".
3. The scale will zero out the weight and you return to the Home
screen.