TROUBLESHOOTING

NOTE: Turn the control knob to "OFF" position first and wait for one minute. Then turn the
control knob to the "ON" position. Please wait for one minute to allow valve to reset.
WARNING:
If you smell gas
·
Shut off gas supply.
·
Do not try to light any appliance.
·
Do not touch any electrical switch; do not use any phone in your building.
·
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
·
If you cannot reach your gas supplier, call the fire department.
WARNING:
Make sure that power is turned off before proceeding.
WARNING:
Turn off and let cool before servicing. Only a qualified service person should service and repair
fireplace.
CAUTION:
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
OBSERVED
PROBLEM
When ignitor button
1. Ignitor is positioned wrong.
is pressed in, there
2. Ignitor electrode is broken.
is no spark at
3. Ignitor electrode is not connected to ignitor
ODS/pilot
4. Ignitor cable is pinched.
5. Damaged ignitor cable.
6. Bad piezo ignitor.
7. Low battery.
When ignitor button
1. Gas supply is turned off or equipment
is pressed in, there
is a spark at
2. Control knob not fully pressed in while
ODS/pilot but no
pilot flame present.
3. Air in gas lines (new installation or recent
4. ODS/pilot is clogged.
5. Incorrect inlet gas pressure or inlet
6. Depleted gas supply
www.PartsFor.com 1-800-446-1446
REMEDY
cable.
shutoff valve is closed.
pressing ignitor button.
gas interruption).
regulator is damaged.
For replacement parts contact:
Replace ignitor.
1.
Replace electrode.
2.
Reconnect ignitor cable.
3.
Free ignitor cable if pinched by any
4.
metal or tubing.
Replace ignitor cable.
5.
6. Replace piezo ignitor.
7. Replace battery.
1.
Turn on gas supply or open equipment
shutoff valve.
2.
Fully press in control knob while
pressing ignitor button.
3.
Continue holding down control knob for
30 seconds to remove air. Repeat
igniting operation until air is removed.
4.
Clean ODS/pilot (see Cleaning and
Maintenance Page 18) or replace
ODS/pilot assembly.
5.
Check inlet gas pressure or replace
inlet gas regulator.
6.
Contact local propane/LP Gas
Company
19