Minimum Wall and Ceiling Clearances
(see Figure 4)
A.
Clearances from outermost point of fireplace
to any combustible side wall should not be less
than 12 inches.
B.
Clearances from the fireplace to the ceiling
should not be less than 48 inches.

CONNECTING TO GAS SUPPLY

WARNING: A qualified technician must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the gas supply. This heater requires an external regulator (not
supplied). The external regulator between the gas supply and heater must be installed.
INSTALLATION ITEMS NEEDED
Before installing heater, make sure you have the items listed below.
·
piping (check local codes)
·
sealant (resistant to propane/LP gas)
·
equipment shutoff valve*
·
test gauge connection**
·
sediment trap
·
tee joint
·
pipe wrench
·
Flexible Gas hose (check local code)
* A CSA design-certified equipment shutoff valve with 1/8
connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer.
WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead
gas.
Figure 5 -Gas Regulator Location and Gas Line Access Into Fireplace Cabinet
www.PartsFor.com 1-800-446-1446
Figure 4 – Minimum Clearance to Wall and Ceiling
"
NPT tap is an acceptable alternative to test gauge
10
For replacement parts contact:
1-866-607-2787