Procom EDP200T-O User Manual page 4

Vent-free fireplace
Hide thumbs Also See for EDP200T-O:
Table of Contents

Advertisement

1.
Do not place Propane/LP supply tank(s) inside any structure. Place Propane/LP supply tank(s) outdoors.
2.
This heater shall not be installed in a bedroom or bathroom.
3.
Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.
4.
Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items
can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater.
After servicing, always replace screen before operating heater.
5.
Make sure the heater screen is in place before running the heater.
6.
This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified
service person. Note: During initial operation, slight smoking could occur due to log curing and the heater
burning manufacturing residues.
7.
To prevent the creation of soot, follow the instructions in Cleaning and Maintenance (page 18).
8.
Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors
from these products may create a white powder residue within burner box or on adjacent walls or furniture.
9.
This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for
Combustion and Ventilation, pages 7 through 9. If heater keeps shutting off, see Troubleshooting, pages 19
through 21.
10. Do not run heater:
Where flammable liquids or vapors are used or stored.
Under dusty conditions.
11. Do not use this heater to cook food or burn paper or other objects.
12. Do not use this heater if any part has been under water. Immediately call a qualified service technician to
inspect the room heater and replace any part of the control system and any gas control which has been
underwater.
13. Turnoff and unplug heater and let cool before servicing. Only a qualified service person should service and
repair heater.
14. Operating heater above elevations of 4,500 feet could cause pilot outage.
15. Do not operate heater if any log is broken. Do not operate heater if any log is chipped (dime-sized or larger).
16. To prevent performance problems, do not use a propane/LP fuel tank of less than 100 lbs capacity.
QUALIFIED INSTALLING AGENCY
Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of
equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm,
corporation, or company that either in person or through a representative is engaged in and is responsible for:
a)
The installation, testing, or replacements of gas piping or
b)
The connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is
familiar with all precautions required; and that has complied with all the requirement of the authority having
jurisdiction.
www.PartsFor.com 1-800-446-1446
4
For replacement parts contact:
1-866-607-2787