WARNING:
fired heater. It uses air (oxygen) f ro m t h e r o o m
i n
w h i c h
i t i s installed. Provisions for ad-
equate combustion and ventilation air must b e
p r o vid ed . R e f er t o A ir F o r Combustion and
Ventilation section on page 5 of this manual.
Continental Appliance Inc./U.S. Office
5 Musick
4600 Highlands Parkway S.E.
Irvine
Suite# D/E
CA 92618
Smyrna GA 30082
CUSTOMER CARE: 1-877-866-5989
Remote Control Fireplace
Remote Control Fireplace
Thermostat Control Fireplace
Thermostat Control Fireplace
This is an unvented gas-
1
OW N E R ' S O P E R AT I O N A N D
INSTALLATION MANUAL
WARNING
is not followed exactly, a f i r e o r e x p l o s i o n m a y
r e s u l t causing property damage, personal injury,
or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l
Do not touch any electrical switch;do not use any
phone in your building.
l
Immediately call
neighbor's phone. Follow the gas supplier's
instructions.
l
If you
cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
WARNING
alteration, service or maintenance can cause injury
or property damage. Refer to this manual for correct
installation and operational procedures. For assis-
tance or additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermarket*,
permanently located, manufactured (mo b ile) h o me,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
Consumer: Please retain these instructions for future
use.
InstaIIer: Please Leave these instructions with the con-
sumer
www.usaprocom.com
FULL SIZE VENT-FREE
FIREPLACE
:
If the information in this manual
your gas supplier from a
: Improper installation, adjustment,
PC-FHL035-01HR/T-0707

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBN400RHA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Procom FBN400RHA Series

  • Page 1 WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. FBN400RHA Series Remote Control Fireplace Do not touch any electrical switch;do not use any FBL400RHA Series phone in your building.
  • Page 2: Table Of Contents

    Table of Contents Make certain you read and understand WARNING Important Safety Information ....2 all warnings. Keep this manual for Models FBN400 are equipped for Natu- Air for Combustion and Ventilation..5 reference. It is your guide to safe ral gas. F ield c on versio n is n ot Installation..........7 and proper operation of this heater.
  • Page 3 SAFETY INFORMATION 17. Do not operate heater if any log State of Massachusetts: The instal- is broken. Do not operate heater Continued lation must be made by a licensed if any log is chipped (dime-sized plumber or gas fitter in the Common- or larger).of 4,500 feet could 8.
  • Page 4 UNPACKING LOCAL CODES lnstall and use heater with care. 1. Remove top inner pack. F o l lo w al l lo c a l c o d e s. In t h e 2. Tilt carton so that fireplace is upright. absence of local codes, use the 3.
  • Page 5: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Confined and Unconfined Space Unusually Tight Construction WARNING : This heater The air that leaks around doors and The National Fuel Gas Code, ANSI shall not be installed in a confined windows may provide enough fresh Z223.1 defines a confined space as a space or unusually tight construc- space whose volume is less than 50...
  • Page 6 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 30,000 Btu/Hr Gas furnace Btu/Hr Vent-free heater 26,000 Btu/Hr Vented gas heater Btu/Hr Total 56,000 Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr...
  • Page 7: Installation

    INSTALLATION NOTICE: This heater is intended for use as supplemen- tal heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system's circulat- ing blower while using heater.
  • Page 8 INSTALLATION Continued CONNECTING TO GAS The installer must supply an external IMPORTANT: Inst all equ ipment SUPPLY regulator. The external regulator will shutoff valve in an accessible location. reduce incoming gas pressure. You The equipment shutoff valve is for WARNING: A qualified techni- must reduce incoming gas pressure turning on or shutting off the gas to cian...
  • Page 9 INSTALLATION Continued CHECKING GAS CON- NECTIONS WARNING: Test all gas piping CAUTION: Make sure external WARNING: Never use an open and connections for leaks after regulator has been installed be- flame to check for a leak. Apply a installing or servicing. Correct all tween gas supply and heater.
  • Page 10 INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts may result in property damage or personal injury. CAUTION: After installation and periodically thereafter, check to en- sure that no flame comes in Figure 10 -Installing Log Set contact with any log.
  • Page 11: Operating Heater, Rha Models

    D. Do not use this appliance if any OPERATING HEATER OPERATIONS OF part has been under water. Imme- FOR YOUR SAFETY REMOTE TRANSMITTER diately call a qualified service techni- RHA Series Models cian to inspect the appliance and to 1. Install three AAA batteries in the replace any part of the control system battery holder.
  • Page 12 OPERATING HEATER Continued Set temperature: Press “Temp” 8. Keep Control Knob depressed for MANUAL OVERRIDE button, then press to set desired ▼ ten (10) seconds after lighting CONTROL SYSTEM OPERATING room temperature. Burner will operate pilot. If pilot goes out, repeat steps INSTRUCTIONS to maintain set room temperature.
  • Page 13: Cleaning & Maintenance

    PILOT FLAME PATTERN DISCONNECT FAN F igu re 15 sh ow s a c o rrec t p ilo t Remove screws from the fan flame pattern. Figure 16 shows an bracket panel , pull the fan bracket incorrect pilot flame pattern. The panel out to remove.
  • Page 14 CLEANING AND MAINTENANCE Continued Exterior inlet hole about two inches from Use a soft cloth dampened with a where the pilot flame comes out of mild soap and water mixture. Wipe the pilot assembly (see Figure 22). the cabinet to remove dust. With the unit off, lightly blow air LOGS through the air inlet hole.
  • Page 15: Specifications

    SPECIFICATIONS FBL400TYLA FBN400TYLA FBL400RHA FBN400RHA Btu(Variable) 40000 40000 Gas Type LP Gas Natural Gas Ignition Piezo/Automatic Piezo/Automatic Manifold Pressure 9"W.C. 4"W.C. Inlet Gas Pressure (In. of water)* Maximum 14" 10.5" Minimum 11" 5" Voltage Watt Mantel A Dimensions, Inches (H × W × D) Heater 45 5/8”...
  • Page 16: Troubleshooting

    7. Check the wine and make wine 7. W ire is not correct or loosen correct. 8. Contact dealer or procom. 8 Gas valve is damage 1. Thermocouple connection loose 1. Hand tighten until snug, then ODS/pilot lights but flame is continu- at control board tighten 1/4 turn more.
  • Page 17: Replacement

    If they can’t supply original re- of your heater parts. This will protect your warranty placement part(s) call ProCom’s toll free How heater was malfunctioning coverage for parts replaced under number at (1-877-886-5989) for referral Type of gas used (propane/LP or warranty.
  • Page 18: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. W hen ordering parts, follow the instructions listed under Replacement Parts on page 17 FBN400TYLA series of this manual. FBL400TYLA series QU ALITY K EY NO PAR T N UMB ER D ESC R IPTION LP N G SIT545...
  • Page 19 PARTS LIST This list contains replaceable parts used in your heater. When ordering FBN400TYLA5 parts, follow the instructions listed under Replacement Parts on page 17 of this manual. FBL400TYLA5 QUALITY KEY NO PART NUMBER DESCRIPTION LP NG FBB500 LOGS FB-01A5M TOP PANEL FB-04A5M SIDE PANEL...
  • Page 20 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 FBN400TYLA series of this manual. FBL400TYLA series QUALITY PART NUMBER DESCRIPTION FBB500 LOGS FB-01AM TOP PANEL FB-04AM SIDE PANEL FB-05AM...
  • Page 21 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 FBN400RHA of this manual. FBL400RHA QUALITY KEY NO PART NUMBER DESCRIPTION LP NG 2020-22 OVERRIDE CONTROL SYSTEM FHL031-01R DOUBLE CONTROL VALVE BRACKERT FBB330RH...
  • Page 22 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 FBN400RHA of this manual. FBL400RHA QUALITY PART NUMBER DESCRIPTION FB-01A4 TOP PANEL FB-02A4 UPPER PANEL FB-05A4 BASE FB-03A4 SIDE PANEL...

This manual is also suitable for:

Fbl400rha seriesFbn400tyla seriesFbl400tyla series

Table of Contents