OBSERVED
PROBLEM
White powder
1. When heated, the vapors from furniture
residue forming
within burner box
or on adjacent
walls or furniture
When ignitor button
1. Ignitor is positioned wrong.
is pressed in,
2. Ignitor electrode is broken.
3. Ignitor electrode is not connected to
4. Ignitor cable is pinched or wet.
5. Broken ignitor cable.
6. Bad piezo ignitor.
When ignitor button
1. Gas supply is turned off or
is pressed in, there
is no spark at
2. Control knob not fully pressed in
ODS/pilot.
3. Air in gas lines when installed.
4. ODS/pilot is clogged.
5. Gas regulator setting is not correct.
6. Bad piezo ignitor.
7. Depleted gas supply.
ODS/pilot lights but
1. Control knob is not fully pressed in.
flame goes out
2. Control knob is not pressed in long
when control knob
is released
3. Equipment shutoff valve is not fully open.
4. Thermocouple connection is loose at the
5. Thermocouple damaged.
6. Control valve damaged.
www.PartsFor.com 1-800-446-1446
REMEDY
polish, wax, carpet cleaners, etc., turn
into white powder residue.
ignitor cable.
shutoff valve is closed.
pressing ignitor button.
enough.
control valve.
For replacement parts contact:
1. Turn heater off when using furniture
polish, wax, carpet cleaner or similar
products.
1. Replace ignitor.
2. Replace ignitor.
3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry.
5. Replace ignitor cable.
6. Replace piezo ignitor.
equipment
1. Turn on gas supply of open
equipment shutoff valve.
while
2. Fully press in control knob while
pressing ignitor button.
3. Continue holding down control
Repeat igniting operation
moved.
4. Clean ODS/pilot (see Cleaning
Maintenance Page 18) or
ODS/pilot assembly.
5. Replace gas regulator.
6. Turn control knob to Pilot position.
7. Contact your local gas company.
1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob
pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, and then tighten
1/4 turn more.
5. Replace thermocouple.
6. Contact Dealer or Customer Service.
21
1-866-607-2787
POSSIBLE CAUSE
until air is
replace
knob.
and