INSTALLATION AND CONNECTION
A 120 volt, 60 Hz, AC only, 20 amp, fused electrical
supply is required. A time-delay fuse or circuit breaker
is recommended. It is recommended that a separate
circuit serving only this appliance be provided.
This washer is equipped with a power supply cord
having a grounded 3 prong plug.
To minimize possible shock hazard, the cord must
be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with local codes and
ordinances. If a mating outlet is not available, it is the
personal responsibility and obligation of the customer
to have the properly grounded outlet installed by a
qualifi ed electrician.
If codes permit and a separate ground wire is used, it
is recommended that a qualifi ed electrician determine
that the ground path is adequate.
Do not ground to gas pipe.
Check with a qualifi ed electrician if you are not sure
the washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.

Grounding Instructions:

For a grounded, cord-connected washer:
This washer unit must be grounded. In the event of
a malfunction or breakdown, grounding will reduce
the risk of electrical shock by providing a path of
least resistance for electric current. This washer is
equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
WARNING:
!
Electrical Shock Hazard
Improper connection of the equipment-
grounding conductor can result in a risk
of electrical shock. Check with a qualifi ed
electrician or serviceman if you are in
doubt as to whether the appliance is
properly grounded. Do not modify the
plug provided with the appliance– if it
will not fi t the outlet, have a proper outlet
installed by a qualifi ed electrician.
GW_40TM09
®
PART 2 INSTALLATION AND CONNECTION
11
Before using the washer, check that all electrical
protection systems are working correctly.
Attention: The machine should not be regarded
isolated from the power supply unless
at the customer's main switch or unplugged.
Chemical Connection:
Use a qualifi ed detergent/chemical supplier for your
detergent, rinse aid, and sanitizer needs.
The machine is supplied with a chemical dispensing
system that is internally wired and ready for
use. Position the chemical bottles close to the
Glasswasher making sure that they will not be prone
to being knocked over or interfere with normal activity
around the Glasswasher. Insert the color coded
pickup tubes into the correct containers.
The RED tube is for a nonchlorinated, non foaming,
commercial detergent recommended for your
Glasswasher by your local detergent/chemical
supplier.
The CLEAR/WHITE tube is for a chemical sanitizer
using a sodium hypochlorite solution or an iodine
based sanitizing solution, as recommended by your
local detergent/chemical supplier.
The BLUE tube is for a low temperature rinse aid
recommended by your local detergent/chemical
supplier for the Glasswasher.
A priming push button switch for each of the
chemicals is located on the front of the control
box. Press and hold the priming switches until the
chemical is seen being dispensed into the wash
sump.
A speed potentiometer is located on the underneath
side of the control box for adjusting the delivery of
the chemicals. This adjustment should be left for a
qualifi ed person to perform.
Final Tasks:
The washer must be connected to all services
(electricity supply and to the fresh water and waste
water systems), prior to testing the machine &
installation.
www.insingermachine.com