INSTALLATION AND CONNECTION

Check for Completeness:
After unpacking the machine, fi rst check the delivery
against the packing slip to ensure that it is complete,
and inspect for damage that may have occurred
during transportation. Immediately report any
damage to the carrier, the insurance company and
the manufacturer.
Setting Up and Alignment:
When setting up the machine, remember that the
machine gives off steam during operation (when you
open the door). Protect adjacent wooden furniture to
prevent it absorbing moisture and swelling.
CAUTION:
Protect the washer against frost. Systems that carry
water can be damaged if they freeze.
The machine must be completely level when in-
stalled. Adjust the machine's feet to compensate for
any unevenness of the fl oor.
CAUTION:
Note all the information on the enclosed connection
diagram. For the machine to work correctly, the required
water pressure and fl ow rate must be
guaranteed at all times.

Connection to the Water Supply:

All plumbing connections must comply with all
applicable local, state, and national plumbing codes.
Flush the incoming water supply to remove all foreign
debris prior to connecting to the unit.
Connect the hot water (120°F minimum) supply
hose (1/2"IPS) from the fi ll solenoid valve located
behind the front panel on the right side to the
building water supply. Recommended installation
includes the use of a ball valve (supplied by others).
A pressure regulator (supplied by others) is required
if the water pressure fl uctuates or is greater then the
recommended pressure (22psig). The unit has a built
in air gap. A vacuum breaker is not required.
GW_40TM09
®
PART 2 INSTALLATION AND CONNECTION
10

Connection to the Drain:

The unit is equipped with a 2" OD drain connection
and must be connected to drain capable of handling
a 9.0 gal/min fl ow. A proper air gap must be supplied
between the unit and the building drain connections.
Failure to provide air gap will result in improper or
inconsistent draining of unit and potential overfl ow
condition.
Connection to the Power Supply:
Electrical and grounding connections must comply
with all applicable portions of the National Electric
Code (ANSI/NFPA 70) and/or other electrical codes
that may apply.
The unit is 115 volts and the total amp load is 14
fl a for the washer without the optional maintenance
heater and 16.0 fl a for the washer with the optional
maintenance heater. The unit is internally wired so
that the wash pump and the optional maintenance
heater do not operate at the same time.
WARNING:
!
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow-these instructions can
result in death, fi re, or electrical shock.