Digital output: choose a voltage level at the camera alarm output:
 High: the alarm output is activated when the voltage level increases from 0 to 12 V.
 Low: the alarm output is activated when the voltage level decreases from 12 to 0 V.
Trigger condition: select a trigger that activates the alarm output.
Select the option for [Alarm] to activate the alarm output when an event has occurred.
Select the option for [Timer] to activate the alarm output according to the specified schedule. The
time for which the alarm output is active depends on the specified time frames. When the [Timer]
is selected, the [Schedule] button is available and allows you to specify the time frames.
Alarm: choose the desired options to designate the events that activate the alarm output:
 Motion detection: the alarm output is activated when the camera detects motion. To
configure this option, click the [Motion detection] button (appears if the [Motion
detection] box is checked) or go to SETTING – Advanced – Motion detection. For
related information, see
 Audio detection: the alarm output is activated when the camera detects noise. To
configure this option, click the [Audio detection] button (appears if the [Audio
detection] box is checked) or go to SETTING – Advanced – Audio detection. For
related information, see
 Network link down: the alarm output is activated once the connection is lost. To
configure this option, go to SETTING – Advanced – Alarm buffer. For related
information, see
N35110 Operations User Manual
Pic. 7.18
paragraph
7.9.
paragraph
7.10.
paragraph
7.8.
Chapter 7. SETTING: Advanced