MANIFOLDS AND EXHAUST GAS RECIRCULATION (EGR)
92
Figure 122 Mounting bolts for right exhaust tube
5. Apply anti-seize compound to two M8 x 60 bolts
securing the right exhaust tube assembly to the
exhaust manifold flange with two prevailing torque
nuts. Loosely assembly bolts and nuts.
Figure 123 EGR cooler V-clamp
6. Install steel gasket for EGR cooler.
7. Attach right exhaust tube assembly to EGR cooler
assembly with V-clamp. Do not tighten V-clamp.
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.

Left Exhaust Manifold

Figure 124 Bolt and spacer for left exhaust
manifold
1.
1. Apply anti-seize compound to all bolt threads.
2. Position exhaust manifold gasket.
3. Install left exhaust manifold, using eight M8 x 40
4. Tighten bolts to specified torque (Table 8) and in
Figure 125
EGES295-2
Follow all warnings, cautions, and notes.
© 2006 International Truck and Engine Corporation
Anti-seize compound
prevailing torque hex flange bolts and spacers.
Start with the second bolt from the rear on top.
The hole diameter is smaller, to allow alignment
of the remaining bolts.
the specified sequence (Figure 121).
EBP sensor tube fitting