Check Free Rotation And Housing Rub; Check Axial End Play - International VT 365 Service Manual

2004-2006 model years
Hide thumbs Also See for VT 365:
Table of Contents

Advertisement

ELECTRONICALLY CONTROLLED VARIABLE GEOMETRY
66

Check Free Rotation and Housing Rub

1. Put VGT on a bench with the shaft in a horizontal
position.
Figure 63
Free rotation of VGT shaft
2. Turn VGT shaft by hand; the shaft must spin
freely. Contact with the turbine and compressor
housings is not acceptable.

Check Axial End Play

1. With VGT in a stable position, push the impeller
shaft toward the turbine housing as far as it will
Read all safety instructions in the "Safety Information" section of this manual before doing any procedures.
TURBOCHARGER (VGT)
Figure 64 Axial end play
1.
2.
2. Move shaft back toward the dial indicator.
3. If measurement exceeds specifications, (Table 4)
EGES295-2
Follow all warnings, cautions, and notes.
© 2006 International Truck and Engine Corporation
go. Put tip of dial indicator (Table 6) on end of
the compressor side of the shaft and zero the
indicator.
Dial indicator with magnetic base
Compressor housing
replace VGT.