Postamble

Postamble Status
Usage:
Useful for identifying and controlling incoming data. For example, defining
the postamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Allows the user to enable or disable up to four postamble characters that
Definition:
can be added to the end of the decoded data.
Serial Cmd:
<K142,status,postamble character(s)>
Default:
Enabled
Options:
0 = Disabled
Postamble Characters
Serial Cmd:
<K142,status,postamble
Default:
^M^J
Options:
To enter control characters within a serial command, hold down the control
key while typing the desired character.
Example:
Important: The ASCII characters <, >, and
For <:
<K142h,,3C>
For >:
<K142h,,3E>
For
:
,
<K142h,,2C>
See
ASCII Character Entry Modifier
enter ASCII characters as hex values.
3-34
1 = Enabled (within any protocol)
character(s)>
corresponds to:
carriage return/line
<K142,1,CNTL-m
on page 3-32 for a detailed explanation of how to
feed.
CNTL-j> to enter ^M^J.
can only be entered as hex pairs:
,