Target Pattern
Usage:
Assists users in positioning and locating symbols in the center of the
imager's field of view.
Definition:
The user can control when the targeting system is ON or OFF, and can
save this condition for power-on.
<K750,green flash
Serial Cmd:
Default:
Always ON
Options:
0 = Always OFF
1 = ON only when not in the read cycle
2 = ON only when in the read cycle
3 = Always ON
Always OFF
The target pattern will remain OFF at all times unless overridden by the EZ button or
operational command.
ON Only When Not in the Read Cycle
The target pattern is always ON except during the read cycle. If the EZ button or operational
command overrides this setting, the target pattern will remain on at all times.
ON Only When in the Read Cycle
The target pattern will remain OFF except during the read cycle. If the EZ button or operational
command overrides this setting, the target pattern will remain on at all times.
Always ON
The target pattern is always ON.