Number of Symbols in Field of View

Number of Symbols in Field of View

Definition:
This command allows the user to determine how FLM will behave in relation
to the candidate symbols in the field of view.
Serial Cmd:
<K518,number of symbols in field of
Default:
Any number of symbols
Options:
0 = Any number of symbols
1 = One symbol
2 = More than one symbol
Note: When the number of symbols in the field of view is set to 1, codeword
stitching from all scaled image processes is allowed for PDF417 and
MicroPDF417.
Note: This variable is used in Fast Linear Mode. FLM usually considers
the whole image as one candidate, but when Number of Symbols in
Field of View is set to 2, FLM will try to locate the candidates first and
then decode. The symbols cannot be side-by-side—they must be parallel.
Note: Number of Symbols in Field of View is not supported when Q-
Mode is enabled.