EAN 128 Status (Code 128/EAN 128)
Definition:
When this field is disabled, the imager will not check any Code 128 labels
for conformance to EAN requirements, or perform any special formatting.
When enabled, the imager can read symbols with or without a function 1
character in the first position. If a symbol has a function 1 character in the
first position, it must conform to EAN format. Symbols that conform to EAN
format will also be subject to the special output formatting options available
in this command.
Note: Code 128 status must be enabled for EAN status to be active.
If EAN status is required, the imager will only decode symbols that have a
function 1 character in the first position and that conform to EAN format. All
symbols read will be subject to the special output formatting options available
in this command.
Note: Code 128 status must be enabled for EAN status to be active.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol
output format,application record separator status,application record separator
character,application record brackets,application record padding>
Default:
Disabled
Options:
0 = Disabled
Output Format (Code 128/EAN 128)
In Standard, the imager will not apply special EAN output formatting
Definition:
options.
In Application, the imager will apply the special EAN output formatting
options to decoded EAN-conforming symbols.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,
output
character,application record brackets,application record padding>
Default:
Standard
Options:
0 = Standard
Application Record Separator Status (Code 128/EAN 128)
Definition:
When enabled, an EAN separator will be inserted into the output between
fields whenever an EAN-conforming symbol is decoded and EAN output
formatting applies.
<K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,
Serial Cmd:
output
character,application record brackets,application record padding>
Default:
Disabled
Options:
0 = Disabled
Quadrus MINI Imager User's Manual
1 = Enabled
format,application record separator status,application record separator
1 = Application
format,application record separator
1 = Enabled
Symbologies
length,EAN 128
2 = Required
status,application record separator
status,
6-13