Replacing a Cooling Fan

There are six cooling fans in the system.
Open the system doors.
1.
CAUTION: The cooling fans are hot-pluggable. To maintain proper cooling while
the system is on, replace only one fan at a time.
Locate the faulty fan. The amber fault indicator adjacent to the fan power connector blinks
2.
if the fan is faulty.
Check the cooling fan power cable connection on the system board or control panel board
3.
(see
Figure
4-5). If the problem is not resolved, install a replacement cooling fan.
Disconnect the fan power cable from the system board or control panel board.
4.
Lift the defective fan out of the power-supply bay or fan bracket (see
5.
Insert the new fan into the power-supply bay or fan bracket.
6.
When replacing the fan, ensure that the finger guard on the fan faces the back of the system
and the fan cable points toward the fan power cable connector on the system board or
control panel board (see
Connect the fan power cable to the system board or control panel board.
7.
If the replacement fan does not operate, the system board is faulty.
8.
NOTE: After installing a new fan, allow up to 30 seconds for the system to
recognize the fan and determine whether it is working properly.
Figure
4-5).
Troubleshooting
Figure
4-5).