Step 1: Log In To The Gateway; Quick Start Guide - LightSand S-2500B Installation And User Manual

Table of Contents

Advertisement

The following guide will allow users who are familiar with the LightSand S-2500B Gateway to
quickly set up a new system at a typical installation.
The basic steps are:
Log in to the gateway
1.
Define the SONET port
2.
Define the termination point
3.
Define the local interface
4.
Verify the FC switches
5.
In addition to the basic procedure, optional commands to set up SNMP monitoring and to
verify the configuration are described below.

Step 1: Log In to the Gateway

Using the supplied serial cable, connect a laptop or other PC to the serial port on the back of
the LightSand Gateway. Use the following port settings:
Bits per second:
Data bits:
Stop bits:
Flow control:
Log in to the gateway with the username: admin, and the password: password. At the CLI
prompt, enter the following command to set up the Ethernet interface:
gateway:> config sys ipaddress <IP-address> <netmask>
where the parameters are the IP address and the network mask of the Ethernet LAN
Management port (for a class C address, the network mask should be 255.255.255.0). If you
need to access the Gateway from a different subnet, you will need to define a default router:
gateway:> config ip default <router-IP-address>
At this point, the LAN port is configured and all remaining steps can be done via Telnet. Exit
the CLI (using the command quit), and disconnect the serial cable.
9600
8
None
Parity:
1
Xon/Xoff

Quick Start Guide