SKEW AND SIDE-TO-SIDE ADJUSTMENT

Where Skew and Side-to-Side Registration Are Measured

Rear
You can measure the skew and registration at two locations.
• At the output slot of the 3000-sheet finisher (B830) [A]
• Inside the booklet finisher (B836) [B] if you remove the upper cover.
At both locations, two scales are provided so that you can visually measure the
amount of skew or deviation in side-to-side registration.
Important! Only one scale is read, depending on the type of paper. Be sure to read
the correct scale for the paper size.
Rear
DLT (11" x 17") size paper only
Front
A3 size paper only
B234/B235/B236/D101/D102/D103
Front
B830I103A.WMF
[A]
1-110
Rear
Front
[B]
B836I109.WMF