LCD Error Message
DRAM Test FAILED
Dynamic Focus Test
FAILED
Filter Wheel Test FAILED Internal startup diagnostic
Horizontal Test FAILED
LCD/Keypad Test FAILED Internal startup diagnostic
Luma Test FAILED
V53-DSP SRAM Test
FAILED
Vertical Test FAILED
Video Test FAILED

Host System Error Messages

Use the following table to troubleshoot and correct error messages appearing on the host
computer during ProPalette operation.
Host System Error Message
Film recorder not connected Film recorder not properly
Possible Cause
Internal startup diagnostic
failure related to DRAM
Faulty dynamic RAM
Internal startup diagnostic
failure
failure
Internal startup diagnostic
failure
failure
Internal startup diagnostic
failure
Internal startup diagnostic
failure
Faulty static RAM
Internal startup diagnostic
failure
Internal startup diagnostic
failure
Possible Cause
connected to host or to AC
power
Plug-in launched before
ProPalette completed
automatic startup and self-
test
107
Troubleshooting and Diagnostics
Corrective Action
Run FPDIAG diagnostics
Replace digital board.
Run MEDTEST diagnostics
Replace analog board
Run FPDIAG diagnostics
Replace digital board
Run MEDTEST diagnostics
Replace analog board
Run FPDIAG diagnostics
Replace digital board.
Run MEDTEST diagnostics
Replace analog board
Run FPDIAG diagnostics
Replace digital board.
Run MEDTEST diagnostics
Replace analog board.
Run MEDTEST diagnostics
Replace analog board.
Corrective Action
Check all cables and
connectors.
Close plug-in, wait for
Ready message on
ProPalette LCD panel,
restart plug-in.