Changing The Stored Serial Number; Viewing And Interpreting The Error Log; Enabling And Disabling The Watchdog Timer - Polaroid 8035 Repair Manual

Propalette 8k series color film recorders
Table of Contents

Advertisement

8K Series ProPalette Repair Manual

Changing the Stored Serial Number

To change the serial number stored in the ProPalette flash memory, execute the following
command:
where <string> is the serial number to be stored in flash memory.
By default, the utility accesses the COM1 port of the host computer.
The utility's help file is accessed with the command: sn ?

Viewing and Interpreting the Error Log

The host-side utility, ERRSTAT.EXE, allows viewing of the ProPalette error log for
troubleshooting purposes. For more information about the error log and messages that
can be stored there, see "Error Logging (ERRSTAT.EXE)" on page 99.

Enabling and Disabling the Watchdog Timer

The ProPalette watchdog timer prevents power-on initialization errors. The watchdog
timer is normally on, but must be disabled for performing some service procedures such
as running the Flash Manager utility described on page 153.
The watchdog timer can be enabled or disabled by changing the position of the jumper on
JP501 of the digital board (1F5570A) as follows:
Watchdog timer enabled: Jump pins 2 and 3 on JP501
Watchdog timer disabled: Jump pins 1 and 2 on JP501
The watchdog timer is also disabled when the ProPalette monitor mode is activated via
the front panel keys as described on page 51.
Hardware Operating Information
sn -burn=<string>